Shark UV440 Vacuum Cleaner Manual

The Shark UV440 is a powerful upright vacuum cleaner featuring UV-C light sanitization technology, HEPA filtration, Lift-Away functionality for portable cleaning, Anti-Allergen Complete Seal, and a motorized brushroll for deep carpet cleaning. It includes multiple attachments for versatile cleaning tasks. Below are key sections for safety, features, assembly, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Assembly & Setup 3. First-Time Use 4. Specifications 5. Controls and Settings 6. Using Attachments 7. UV-C Sanitization Mode 8. Maintenance & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Upright vacuum body with UV-C light module, Lift-Away pod, motorized brushroll, HEPA filter, dust cup, crevice tool, dusting brush, upholstery tool, and power cord.

FeatureDescription
UV-C SanitizationEmits UV-C light to reduce germs, bacteria, and dust mites on surfaces
Lift-Away TechnologyDetachable pod for portable cleaning above floors
Anti-Allergen Complete SealHEPA filtration traps 99.9% of dust and allergens
Motorized BrushrollDeep cleans carpets and agitates embedded dirt
Floor Selector SwitchAdjusts brushroll height for carpets or hard floors
LED HeadlightsIlluminates dark areas under furniture
Large Dust CupEasy-empty, bagless design
AttachmentsCrevice tool, dusting brush, upholstery tool included
Power Cord25-foot cord with cord wrap
Wand Release PedalQuickly detaches wand for above-floor cleaning

Assembly & Setup

Unpack all parts and inspect contents. Assemble on a flat, stable surface.

  1. Attach the handle: Insert handle into the main body until it clicks into place.
  2. Install the wand: Insert the wand into the socket on the back of the vacuum.
  3. Attach hose: Connect the hose to the port on the Lift-Away pod.
  4. Attach floor nozzle: Slide the floor nozzle onto the wand until it locks.
  5. Install filters: Place the HEPA filter and pre-motor filter into their compartments.
  6. Plug into a standard 120V AC outlet.

WARNING! Ensure all parts are securely connected before use. Keep fingers away from brushroll and moving parts.

First-Time Use

Before first use, charge the UV-C module (if applicable) and perform a test run.

  1. Power on: Press the power button on the handle.
  2. Select floor type: Use the floor selector switch (CARPET/HARD FLOOR).
  3. Test UV-C mode: Press the UV-C button to activate sanitization (ensure nozzle is flat on surface).
  4. Empty dust cup: Ensure dust cup is empty before first use.
  5. Check filters: Verify filters are properly installed.

CAUTION! Do not look directly at UV-C light. Keep vacuum upright during use.

Specifications

Controls and Settings

Main controls located on handle and body.

Handle Controls: Power button, UV-C button, floor selector switch (CARPET/HARD FLOOR).

Body Features: Dust cup release button, wand release pedal, brushroll on/off switch (for hard floors), cord wrap hooks.

Settings: Power (On/Off), UV-C (On/Off - activates when nozzle is flat on surface), floor type (adjusts brushroll height), brushroll (On for carpets, Off for hard floors).

Using Attachments

For above-floor cleaning, detach the Lift-Away pod or use the wand with attachments.

  1. Detach pod: Press the release button on the back to lift away the pod.
  2. Attach tools: Connect crevice tool, dusting brush, or upholstery tool to the hose or wand.
  3. Clean: Use the handle on the pod for portable cleaning of stairs, furniture, and ceilings.
  4. Reattach: Place pod back onto the main body until it clicks.

Tip: Turn off the brushroll when using attachments on delicate surfaces.

UV-C Sanitization Mode

The UV-C light reduces microorganisms on surfaces. Use on carpets and hard floors.

  1. Activate: Press the UV-C button on the handle (LED indicator will light).
  2. Operation: UV-C activates only when the floor nozzle is flat on the surface and the vacuum is moving slowly.
  3. Effectiveness: Move the vacuum slowly over each area for 2-3 seconds for optimal sanitization.
  4. Safety: UV-C turns off automatically when the vacuum is lifted or turned off.

WARNING! Avoid direct eye exposure to UV-C light. Do not use on people or pets.

Maintenance & Cleaning

Regular maintenance ensures optimal performance.

CAUTION! Unplug vacuum before maintenance. Do not use water on electrical parts.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. UL listed. Copyright © SharkNinja Operating LLC. UV-C technology complies with FDA and IEC standards. For support, visit sharkclean.com or contact 1-800-798-7398.

Troubleshooting

SymptomPossible CauseCorrective Action
Vacuum won't turn onPower cord/outletCheck power cord connection; try different outlet; ensure power button is pressed.
Loss of suctionFull dust cup/clogEmpty dust cup; check hose and nozzle for clogs; clean filters.
Brushroll not spinningObstruction/switchClear hair and debris from brushroll; ensure brushroll is set to ON for carpets.
UV-C light not workingBulb/positionEnsure nozzle is flat on surface; replace UV-C bulb if indicator flashes.
OverheatingClog/filterTurn off and unplug; let cool for 60 minutes; check for clogs; clean filters.

Reset: Unplug for 10 minutes, then restart.

Service: 1-800-798-7398; sharkclean.com