Shark UV219CS Vacuum Cleaner Manual

The Shark UV219CS is a versatile upright vacuum cleaner featuring UV-C Sanitizing technology, HEPA filtration, a motorized brushroll for carpets, a lift-away canister for portable cleaning, multiple attachments for above-floor cleaning, and a 30-foot power cord. It is designed for deep cleaning carpets, hard floors, and upholstery while sanitizing surfaces. Below are key sections for safety, features, assembly, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Assembly & Setup 3. First-Time Use 4. Specifications 5. Controls and Settings 6. Using Attachments 7. UV-C Sanitizing Mode 8. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Upright body with motorized brushroll, Lift-Away canister, UV-C Sanitizing light, HEPA filter, Dust cup, Hose, Wand, and multiple cleaning attachments.

FeatureDescription
UV-C Sanitizing TechnologyEmits UV-C light to kill germs and bacteria on surfaces
Motorized BrushrollDeep cleans carpets and agitates embedded dirt
Lift-Away CanisterDetaches for portable cleaning above floors
HEPA FiltrationCaptures 99.9% of dust and allergens
30-Foot Power CordProvides extended reach without unplugging
Multiple AttachmentsIncludes crevice tool, dusting brush, upholstery tool
ON/OFF SwitchPowers the vacuum and brushroll
UV-C ButtonActivates sanitizing light (only in upright mode)
Brushroll On/OffDisengages brushroll for hard floors
Dust Cup ReleaseEmpties collected debris

Assembly & Setup

Unpack and inspect all contents. Assemble before first use.

  1. Attach the handle: Insert handle into upright body until it clicks into place.
  2. Connect the hose: Attach hose to the port on the front of the vacuum.
  3. Install the wand: Insert wand into hose grip until secure.
  4. Attach cleaning tools: Store tools on onboard caddy or attach as needed.
  5. Plug into a standard 120V AC outlet.

WARNING! Ensure vacuum is unplugged during assembly. Keep fingers away from brushroll.

First-Time Use

Before cleaning, perform a quick setup.

  1. Check filter: Ensure HEPA filter is properly seated in the dust cup.
  2. Adjust height setting: Rotate dial at base for carpet (high) or hard floor (low).
  3. Test suction: Turn on vacuum and listen for consistent motor sound.
  4. Test UV-C light: Press UV-C button in upright mode; blue light should illuminate.
  5. Empty dust cup after initial use to ensure optimal performance.

CAUTION! Do not look directly at UV-C light. Keep vacuum away from water.

Specifications

Controls and Settings

Main controls located on handle and body.

Handle: ON/OFF switch, UV-C button (only in upright mode), Brushroll On/Off switch.

Body: Height adjustment dial (for carpet/hard floor), Dust cup release button, Hose release latch.

Settings: Carpet mode (brushroll on), Hard floor mode (brushroll off), UV-C mode (activates sanitizing light). Note: UV-C only works when vacuum is in upright position on a surface.

Using Attachments

For above-floor cleaning, use Lift-Away mode.

  1. Detach canister: Press release button to lift canister away from upright body.
  2. Select attachment: Connect desired tool to wand or hose end.
  3. Clean: Use for upholstery, stairs, ceilings, tight spaces.
  4. Reattach: Place canister back onto upright body until it clicks.

Tip: Turn off brushroll when using attachments on delicate surfaces.

UV-C Sanitizing Mode

UV-C light kills germs on surfaces as you vacuum.

  1. Ensure vacuum is in upright position on floor.
  2. Press UV-C button; blue light indicates activation.
  3. Slowly push vacuum forward over area to be sanitized.
  4. Light turns off automatically when vacuum is lifted or turned off.

WARNING! Do not use UV-C light on humans or pets. Avoid direct eye exposure.

Maintenance & Cleaning

Regular maintenance ensures peak performance.

  1. Empty dust cup: Press release button; empty when cup is 2/3 full.
  2. Clean filters: Rinse HEPA and foam filters every 3 months; air dry 24 hours.
  3. Clear brushroll: Remove hair and debris from brushroll monthly.
  4. Check hose for clogs: Detach and inspect if suction is weak.
  5. Wipe exterior: Use dry cloth; no liquids.

CAUTION! Unplug before maintenance. Ensure filters are completely dry before reinserting.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © SharkNinja Operating LLC. UV-C technology complies with FDA and IEC standards. For support, visit www.sharkclean.com or contact 1-800-798-7398.

Troubleshooting

SymptomPossible CauseCorrective Action
Vacuum won't turn onPower cord/outletCheck plug; try different outlet; ensure ON/OFF switch is pressed.
Loss of suctionFull dust cup/clogEmpty dust cup; check hose, wand, and brushroll for blockages.
Brushroll not spinningEngagement switch/obstructionEnsure brushroll is set to ON; clear debris from brushroll ends.
UV-C light not workingPosition/modeEnsure vacuum is upright on floor; UV-C only works in upright mode.
OverheatingClogged filter/full dust cupClean filters; empty dust cup; let vacuum cool for 60 minutes.

Reset: Unplug for 10 minutes if motor overheats.

Service: 1-800-798-7398; www.sharkclean.com